Visual InspectionsJoints and ConnectionsIt is not practicable to inspect every joint and termination in an electrical installation, nevertheless a sample inspection is made. An inspection is made of all accessible part of the electrical installation e.g. switchgear, distribution boards, and a sample of luminaire points and socket-outlets to ensure that all terminal connections of the conductors are properly installed and secured. Any signs of overheating and conductors, terminations or equipment will be thoroughly investigated and included in the Report. ConductorsThe means of identification of each conductor, including protective conductors, will be verified. The deterioration of, or damage to, conductors and their insulation and their protective coverings, if any, will be noted. NB. Cables coated in black- rubber were phased out in the 1960s or cables coated in lead or fabric are even older and may need replacing (modern cables use PVC insulation). Flexible cables and cordsWhere a flexible cable or cord forms part of a fixed wring installation, the inspection will include:
Accessories and SwitchgearIt is recommended that a random sample of a minimum of 10 per cent of all switching devices is given a thorough internal visual inspection of accessible parts to assess their electrical and mechanical condition. Protection against Thermal Effects The presence of fire barriers, seals and means of protection against thermal effects will be verified. Protection against Direct and Indirect Contact of live parts The means of protection against contact with live parts by means of SELV, direct contact and indirect contact will be verified. Protective DevicesThe presence, accessibility, marking and condition of devices for electrical protection, isolation and switching will be verified. It should be established that each circuit is adequately protected with the correct type, size and rating of fuse or circuit-breaker. The suitability of each protective and monitoring device and its overload setting will be checked. Marking and LabelingThe labeling of each circuit will be verified. Notices or labels are required at the following points and equipment within an installation:
|
![]() |
||||||||||||
|
Domestic Visual Inspection from £75.00
+VAT Periodic Inspection and Testing from £180.00 +VAT Note (Off peak storage heating to be charged additionally per circuit.) Commercial installation testing & certification £22.50 +VAT per circuit (Fuse/circuit breaker in distribution board)
|
|||||||||||||
I carry out electrical safety checks, electrical inspections / inspecting, periodic inspections / inspecting, periodic electrical inspections, tests, inspecting, on domestic properties in Sandbach, Crewe, Alsager, Holmes Chapel, Nantwich, Middlewich, Northwich, Alderly Edge, Wilmslow, Knutsford, Cheshire
I carry out electrical safety checks, electrical inspections / inspecting, periodic inspections / inspecting, periodic electrical inspections / inspecting, on domestic properties in North Staffs / Staffordshire.
I carry out electrical safety checks, electrical inspections / inspecting, periodic inspections / inspecting, periodic electrical inspections, tests, inspecting, on domestic properties in Sandbach, Crewe, Alsager, Holmes Chapel, Nantwich, Middlewich, Northwich, Alderly Edge, Wilmslow, Knutsford, Cheshire
I carry out electrical safety checks, electrical inspections / inspecting, periodic inspections / inspecting, periodic electrical inspections / inspecting, on domestic properties in North Staffs / Staffordshire.